Replacing media drives
Hard drive bay
6 (far right)
a. RAID pairs (logical drives) consist of the following pairs: hard drives 1

To replace hot-pluggable SCA SCSI hard drives

.
1
Ensure the new hard drive has the SCSI ID set to 0, termination
disabled, and parity checking enabled.
2
Open the front bezel doors.
3
Locate the SCA SCSI drive frame below a cooling fan and beside
the media drive.
4
Loosen the two thumbscrews on the carrier of the faulty hard drive,
and remove the carrier from the chassis.
142
SCSI
channel
1
and 4, 2 and 5, and 3 and 6. These pairs are represented in the software with
A01-01
the labels
A03-02
and
, where the first number is the logical drive number (for
example, A03) and the second number indicates if it is the primary or
secondary hard drive (01 for primary and 02 for secondary).
CAUTION
Risk of equipment damage
Use an ESD wrist strap to protect static-sensitive components.
SCSI ID Logical drive label
2
A01-02, A02-01
and
A03-02 (secondary hard drive)
A02-02,
and
and
Standard 1.11
a
A03-01
CallPilot