Replacing A Faulty Hard Drive - Nortel 1002rp Maintenance And Diagnostics

Callpilot
Table of Contents

Advertisement

Replacing media drives

Replacing a faulty hard drive

The hard drives are hot-swappable. This means that you can replace a
faulty hard drive without powering down the server.
When to hot-swap hard drives
With a RAID controller, hot-swap device drivers, and operating system
support, faulty SCA SCSI hard drives can be hot-swapped on the 1002rp
server.
Note: Identify which hard drive to remove using the Windows Event
Viewer (see "Viewing event logs" on page 33). The appearance of event
codes such as 40211(disk access error) or 40218 (error reading or writing
multimedia volume) may be an indication of a failing disk drive.
Use the RAID management software to check if any drives are in a failed
state.
The following image shows a failed drive highlighted in red with the
corresponding logical drive highlighted in yellow (degraded mode)
140