Configure an E1/T1 card
Use
Configuring the PRI2 loop timers using LD 73
timers and thresholds.
Configuring the PRI2 loop timers using LD 73
1. Log on to the CS 1000E.
2. To access LD 73, enter:
3. Enter the responses shown in
94
Media Gateway 1000E PRI Gateway Installation and Commissioning
Prompt
Response
MGCLK
sl s c
- PREF
Card
- SREF
Card
...
...
LD 73
page 94.
Table 26: PRI2 loop timers and thresholds (LD 73)
Prompt
Response
REQ
aaa
TYPE
PRI2
FEAT
LPTI
LOOP
loop
MFF
aaa
ACRC
(NO) YES
ALRM
aaa
RAIE
(NO) YES
Comments? infodev@avaya.com
Description
To modify, use the CHG command (you can
change the PREF only if you change the
MGCLK).
Superloop, shelf, card number of PRI2 containing
the Primary Clock Reference for the second
IPMG.
The card number (1 - 8) should match the span
number configured through the Web interface.
Clock Reference for the second IPMG.
Card number of PRI2 containing the Secondary
Clock Reference for the second IPMG.
To modify, use the CHG command (the PREF
cannot be changed unless the MGCLK is
changed).
on page 94 to configure the PRI2 loop
Table 26: PRI2 loop timers and thresholds (LD 73)
Description
Request (aaa = CHG, END, NEW, OUT, or
PRT).
DTI2 and JDMI are not supported for the PRI
Gateway.
Feature = SYTI (System Timers).
Loop number for PRI2.
Multiframe format (aaa = AFF or CRC).
Automatic reporting of CRC-4 error.
Default alarm handler selected (aaa = REG or
ALT).
RAIE Group II alarm state enabled or disabled.
on