Configure an E1/T1 card
4. Note the Media Gateway Card (MG_CARD) value.
5. Return to the Routes and Trunks » D-Channels page.
6. Click the MSDL Diagnostics (LD 96) link.
7. From the menu, select disable MSDL Device (DIS) and select the All check box.
8. Select the radio button for the MSDL (MG_Card).
9. Click Submit.
10. Click OK
11. Return to the D-Channel configuration page and make the required changes.
12. Return to the MSDL diagnostics page.
13. From the menu, select the enable MSDL Device (ENL) command and select the
14. Select the radio button for the MSDL (MG_Card).
15. Click Submit.
16. Click OK
Configuring the DPNSS/DASS trunks with Trunk Data Block data using LD 14
describes how to configure the DPNSS trunks with Trunk Data Block data. This configuration
is required for both real (RDC) and virtual (VDC) channel types.
Important:
VDC configuration is not required for DASS signaling.
Configuring the DPNSS/DASS trunks with Trunk Data Block data using LD 14
1. Log on to the CS 1000E.
2. To access LD 14, enter:
3. Enter the responses shown in
100
Media Gateway 1000E PRI Gateway Installation and Commissioning
The property page for the D-channel appears.
The MSDL Diagnostics page appears.
All check box.
LD 14
trunks (LD 14)
on page 100.
Table 31: Trunk Data Block data for DPNSS/DASS trunks (LD 14)
Prompt
Response
REQ
aaa
TYPE
RDC/VDC
TN
l ch
DES
DPNSS
Comments? infodev@avaya.com
Table 31: Trunk Data Block data for DPNSS/DASS
Description
Request (aaa = CHG, NEW)
Real/virtual digital channel.
Terminal Number for digital trunks where l=loop,
ch=channel.
Designator field for trunk.
on page 100
March 2013