Use the steps in
LD 17
on page 87 to configure the PRI2/Euro D-channel interface for the PRI Gateway.

Configuring a D-channel interface to support PRI2/EURO D-channels using LD

17
1. Log on to the CS 1000E.
2. To access LD 17, enter:
3. Enter the responses shown in
Media Gateway 1000E PRI Gateway Installation and Commissioning
Prompt
Response
USR
PRI
IFC
NI2
DCHL
0 - 254
SIDE
(USR) NET
...
...
Configuring a D-channel interface to support PRI2/EURO D-channels using
LD 17
configuration (LD 17)
Table 20: PRI2/Euro D-channel interface configuration (LD 17)
Prompt
Response
REQ
CHG
TYPE
ADAN
ADAN
NEW DCH xx
CTYP
MSDL
Important:
If configuring the NTBK51AA dual D-channel
daughterboard on a MG1000E PRI Gateway,
do not configure port 0 as the backup D-
channel. This generates a SCH4765 error
message and causes the configuration build to
fail. You must configure backup D-channels on
port 1 of the D-channel daughterboard.
Important:
For the PRI Gateway, the following software
package for the functionality that allows the
use of port 0 or port 1 is provided in CS 1000
Extended Media Gateway PRI (MGP) package
418
This D-channel is used for Primary Rate only.
Interface type for the D-channel.
Loop number for the D-channel. (See DLOP loop
number.)
The system is network/user side.
Table 20: PRI2/Euro D-channel interface
on page 87.
Change existing data.
Action device and number.
Add a D-channel on logical port 0 - 254.
D-channel configuration on MSDL card.
Configure E1/T1 ports on a Call Server
Description