Configuring Secure Web Access; Configuring The Basic Settings - Juniper JSA7500 Secure Analytics Hardware Manual

Hide thumbs Also See for JSA7500:
Table of Contents

Advertisement

CHAPTER 15

Configuring Secure Web Access

IN THIS CHAPTER

Configuring the Basic Settings | 99

Accessing the JSA Interface | 102
Configuring the Basic Settings
NOTE: When deploying a Juniper Secure Analytics (JSA) appliance with image
2013.2.r3.607582, you must reimage the appliance to the common image 2013.2.r3.615469 or
above. For more information, see
Note.
To configure the basic setting using the JSA interface:
NOTE: When using a laptop to connect to the appliance, you must use a terminal program, such
as HyperTerminal, to connect to the appliance.
1.
Power on the system.
2.
Select the appropriate COM port to use.
3.
Configure the following port settings:
• Bits per second = 9600
• Stop bits = 1
• Data bits = 8
• Parity = None
4.
At the console prompt, log in as root (default username). No password is required when you log in
for the first time.
Installing JSA Using a Bootable USB Flash-Drive Technical