Power Supply - Juniper JSA7500 Secure Analytics Hardware Manual

Hide thumbs Also See for JSA7500:
Table of Contents

Advertisement

• For RAID10 status: /opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -LAll –a Ø
• For JSA7500 RAID consistency check, schedule through cron or use /opt/MegaRAID/MegaCli/
MegaCli64 -LDCC -Start -Lall -a Ø.
RELATED DOCUMENTATION
Hardware Specifications | 6
JSA7500 Front Panel | 10
JSA7500 Back Panel | 12

Power Supply

The JSA7500 appliance ships with redundant DC power supplies and also supports AC power supply
option if you need AC power.
To maintain the power supplies, follow these guidelines:
• Ensure that the power and grounding cables are arranged so that they do not obstruct access to
other components.
• Routinely check the power LED on the power supply module. If the LED status is green, the power
supply is functioning normally.
• Periodically inspect the site to ensure that the grounding and power cables connected to the JSA
appliance are securely in place and that there is no moisture accumulating near the appliance.
To monitor the power supply modules, execute the following files which are available at the Juniper
Customer Support website, www.juniper.net/support/downloads:
• Install rpm –ivh i2c-tools-3.1.0-1.el6.x86_64.rpm
• ./pwr_status_jnpr.sh