2. Connect the stripped and twisted wires to wire clamps under DC terminal screws as shown in
5 on page
81.
Figure 5: Connecting JSA to a DC Power Source
DC ring lug
1
Screw
2
3. Use the terminal screws to secure the power source cables to the power feed on the JSA appliance
by attaching the twisted wires that are attached to the cables to the appropriate terminals.
NOTE: The red cable should be connected to the V+ terminal, and the black cable should be
connected to the V- terminal, respectively, as shown in
4. Attach the plastic safety cover.
RELATED DOCUMENTATION
Connecting to a Management Device | 82
Installing the CNA Module on the JSA7500 Appliance | 94
Safety cover
3
Figure 5 on page
81.