CHAPTER 8
Power and Electrical Safety Information
IN THIS CHAPTER
General Electrical Safety Guidelines and Warnings | 47
General Electrical Safety Guidelines and Warnings
WARNING: Certain ports on the device are designed for use as intrabuilding (within-
the-building) interfaces only (Type 2 or Type 4 ports as described in
Issue 4) and require isolation from the exposed outside plant (OSP) cabling. To protect
against lightning surges and commercial power disturbances, the intrabuilding ports
must not be metallically connected to interfaces that connect to the OSP or its wiring.
The intrabuilding ports on the device are suitable for connection to intrabuilding or
unexposed wiring or cabling only. The addition of primary protectors is not sufficient
protection for connecting these interfaces metallically to OSP wiring.
GR-1089-CORE ,