TIENet™ 360 LaserFlow™ Velocity Sensor
Section 4 Setup with 2160 LaserFlow Module

4.2.3 Advanced Settings

Figure 4-8 360 Velocity Tab: Advanced settings
A - Input Velocity Coefficients
4-8
The LaserFlow Advanced Settings are pre-programmed into the
sensor. However, if your application requires the any custom con-
figuration, the "Advanced" button opens the Velocity Coeffi-
cients window (refer to Figure 4-8).
A
B
C
D
E
F
G
H
Input Velocity Coefficients – The relationship of the three
Input Velocity Coefficients A, B and C can be expressed as:
V = A (offset) + B*(Measured Velocity) + C*(Measured Velocity)
Coefficient A is an additive offset value to correct the Measured
Velocity for any additive bias. The value for A must be expressed
in units of meters/second. The default is "0".
Coefficient B is a multiplicative scalar for correcting the Mea-
sured Velocity for any linear multiplicative bias. The value for B
is unitless. The default is "0.9".