Teledyne TIENet LaserFlow 360 Installation And Operation Manual page 62

Velocity sensor
Hide thumbs Also See for TIENet LaserFlow 360:
Table of Contents

Advertisement

TIENet™ 360 LaserFlow™ Velocity Sensor
Section 3 Setup with Signature® Flow Meter
Figure 3-5 Measurement setup: Advanced settings for LaserFlow sensor
3-8
Advanced
Warning: Any changes to the
following data can adversely
affect the performance of this
Instrument!
Select BACK to cancel or NEXT to
continue.
A + (B * v) + (C * v
2
)
Input Velocity Coefficients
A (default=0):
B (default=0.9):
C (default=0):
Spectral Averages
(default=5000):
Re-home Count
(default=100):
Start Bin:
Maximum Focus Depth:
Focus Learning Algorithm
Peak Detect
Adaptive Focus
Remote Distance Measurement
US Distance to Bottom
LaserFlow Distance to Bottom
LaserFlow Directional Velocity
Focus Downstream
Maximum Distance:
Maximum Velocity:
Steep Slope LaserFlow Focusing
Enable Slope Setting
Parallel to Channel Slope
Slope Percentage:
Optical Clarity
Active
Passive
OK
0
m/s
0.9
0
s/m
5000
100
7
0.5
ft
in
in
Horizontal Mount
1
ft
1
ft/s
%
Cancel
For use with the
remote 360 ultrasonic
level sensor.

Advertisement

Table of Contents
loading

Table of Contents