TIENet™ 360 LaserFlow™ Velocity Sensor
Section 5 Maintenance and Optional Kits
Figure 5-7 Reassembling the LaserFlow w/ AV sensor installed
5.8 Installing the Remote
TIENet™ 310
Ultrasonic Level
Sensor
5-10
5. Route the 350 sensor cable through the slot in the bottom
of the nose piece. Route the LaserFlow cable through its
slot in the top of the nose piece.
Taking care not to pinch or bind the cables, bring the two
sections of the sensor housing back together.
6. Reassemble the LaserFlow housing, following the steps
provided in Section 5.4.2 Replacing the Nose Piece.
When reinstalling all self-tapping screws, avoid destroying the
plastic threads. First seat each screw in its hole and, without
pressing down, rotate the screw counter-clockwise until it falls
into its thread groove with a "click." Then tighten the screw.
Refer to the TIENet™ 310 Ultrasonic Level Sensor Installation
and Operation Guide for details.