Installing The Sensor Carrier - Teledyne TIENet LaserFlow 360 Installation And Operation Manual

Velocity sensor
Hide thumbs Also See for TIENet LaserFlow 360:
Table of Contents

Advertisement

Adjust carrier, tighten bolts (4)
Figure 2-28 Installing the sensor carrier
TIENet™ 360 LaserFlow™ Velocity Sensor
9. Slide the pipe up through the coupler tube. Replace the
other pipe cap.
10. Rotate the carrier to proper orientation and tighten the 4
bolts on the coupler tube.
11. Fine-tune the carrier orientation and tighten the 2 bolts on
the carrier knuckle.
Note
After initial installation and sensor alignment, the remaining
steps are often possible to perform from above ground with the
optional sensor retrieval arm.
If lowering the LaserFlow from above ground, ensure that
it does not become dislodged while being lowered, possibly
endangering any personnel who may still be below ground.
12. Lower the LaserFlow sensor onto the mounting bracket
between the front and rear alignment tabs, with the two
mounting block grooves resting on the two carrier arms.
The sensor can be installed on the carrier facing inward or
outward, depending on installation requirements.
Section 2 Preparation and Installation
Finely adjust carrier, tighten bolts (2)
WARNING
2-25

Advertisement

Table of Contents
loading

Table of Contents