TIENet™ 360 LaserFlow™ Velocity Sensor
Section 3 Setup with Signature® Flow Meter
Figure 3-7 Submerged functionality: Initial 350 Level setting
3.2.5 350 Velocity (Optional)
3-10
Bottom of Channel
If your system includes the optional submerged functionality or
redundant measurement, it is also capable of measuring velocity
with a continuous wave Doppler sensor.
The Measure positive velocity only setting causes any negative
readings to be discarded in the average velocity calculation. If
this is set to false, both positive and negative readings are used.
Bottom of LaserFlow