SmartCombi™ & ClassicCombi™ Service
WaveClean pump replacement instructions
Valid for:
MM203825 MM203826
Disassembling:
Remove left side wall.
Preparations before removing the WaveClean cycle pump: Carry out the relay test K24 at the Service
menu „777". The trap will be emptied by the WaveClean drain pump.
Preparations before removing the WaveClean drain pump: : Remove air baffle. Carry out the relay test
K16 at the Service menu „777". The WaveClean cycle pumps now the water from the trap into
cabinet. Collect the water with a container until no water will be cycled anymore
Disconnect unit from the power supply. Close water tap on site.
Mounting instructions for the WaveClean cycle pump 615, 620, 115, 120:
1
Remove screw from the left protection box [1].
➢
3
Loosen clamp [2] and pull hose from the pump.
➢
Remove wires from the pump[3].
➢
Assembling:
The assembly
has to be
➢
exchanged.
Switch on the power and open water tap.
➢
Final function test with the help of the service menu -> WaveClean Test. Close side wall.
➢
2
carried out in reversed order. The gasket [5] (#211131) between pump and trap should be
Remove protection box
➢
5
Remove nuts [4] and remove pump from the trap!
➢
Note, that water could leak out of the trap!
No.31 HD_02/2008
4
Page 1 of 3
44