Drain Solenoid Valve Replacement Instructions - Henny Penny SmartCombi ESC 615 Replacement Instructions Manual

Combi oven
Hide thumbs Also See for SmartCombi ESC 615:
Table of Contents

Advertisement

SmartCombi™ & ClassicCombi™ Service

Drain solenoid valve replacement instructions

Valid for:
MM201192
MM201193 MM201160
Arrangements:
Disconnect unit from the power supply. Close water tap on site and relieve pressure on the supply site.
Remove left side panel.
Disassembling:
2
1
3
Variant A (Units with
hand shower )
Remove plugs from the valve [1].
Variant A: Loosen clamp [2] and screwed fitting [3]. Remove hose.
Variant B: Loosen clamp [4] land remove hose. Afterwards remove the mounting screws from the
bottom plate [5] and remove holding plate [6].. Take out the water filter [7] and clean, if
necessary.
Assembling:
The assembly
has to be
(MM201134) has inserted.
Final function test with the service menu ( -> 11 Drain cooling test) .Close side wall.
1
5
Variant B (Units without hand shower)
carried out in reversed order. Ensure that the water inlet filer [6]
No.30 HD_02/2008
4
6
5
7
43