4.2 WaveClean
Functional overview
Description 1. Testing the cooking chamber temperature.
a
b
a Magnetic valve K12
b Pump G16
The following purification stages are available on the fully automatic
cleaning WaveClean:
•
Short: duration of about one hour
•
Normal: duration about two hours
•
Extra: duration approximately three hours
Automatic cooling of the cooking chamber, if > 55°C.
2. Inserting the WaveClean cartridge.
3. Water exchange of siphon content by the siphon pump G24 and
solenoid valve K12.
4. Circulation of water by means of pump G16. Thus pre-cleaning of
the cooking chamber. Then anew siphon water exchange.
The heater heats the oven to 55°C.
5. Start cleaning.
Fan motor and WaveClean pump G16 active.
Heating active. Heating the cooking chamber to about 70°C.
The first layer of wax melts in the WaveClean cartridge. The
cleaner falls into the cooking chamber and mixes with water.
The fan motor operates in both directions of rotation and at
different speeds.
The cleaning phase duration depends on the selected
program.
Service instructions
Description of operation
c
c Pump G24
11