SmartCombi™ & ClassicCombi™ Service
Lift magnet replacement instructions
Valid for:
SmartCombi ClassicCombi MM203672 MM202621
Arrangements:
Disconnect the unit from the power supply. Remove the left side wall
Disassembling:
2
1
2
Remove plugs from the supply
➢
cables and unscrew cable
connection.
Unfasten both clamps [2].
➢
Pull silicon hose [3] upstairs.
➢
Assembling:
4
3
Dismount both screws [4] and
➢
remove lift magnet [5].
The assembly
➢
Replace seal [7] #211080 if necessary
➢
The lift mechanism has to be glued with thread locker (etc. Loctite).
➢
The height of stroke [8] must be between 5 – 7 mm.
➢
Pull cables through the cable connection and mount plugs #203730.
➢
Carry out a final check with the help of the service area.
➢
(Configuration menu -> 5 Relay-Test -> K8 Lift magnet)
Mount left side wall.
➢
8
7
5
Dismount lift mechanism [6].
➢
has to be
carried out in reversed order.
No.15 HD_03/2008
6
26