SmartCombi™ & ClassicCombi™ Service
Cooling fan replacement instructions
Valid for:
SmartCombi & ClassicCombiUnits with hand shower :
ClassicCombi without hand shower:
Arrangements:
Disconnect unit from the power supply.
Disassembling:
Concerns all units with hand shower as well as all
floor versions (2xx):
1
Sample at unit version 6.x / 10.x (Version 20.x ist equipped
with two cooling fans)
Remove left side wall
➢
Disconnect electrical connections at the
➢
cooling fan.
Remove mounting screws [1].
➢
Take out cooling fan.
➢
Assembling:
The assembly
has to be
carried out in reversed order.
MM202607 MM203926
MM202617 MM203819
Concerns units 6xx and 10xx without hand
shower:
Unlock and open front panel.
➢
Disconnect electrical connections at the
➢
cooling fan.
Unlock securing clip [2].
➢
Take out cooling fan
➢
No.35 HD_04/2008
2
50