Henny Penny SmartCombi ESC 615 Replacement Instructions Manual page 15

Combi oven
Hide thumbs Also See for SmartCombi ESC 615:
Table of Contents

Advertisement

SmartCombi™ & ClassicCombi™ Service
Parameter-No.
Core temperature
246
probe
2 wires at terminal X12 = Single point probe
5 wires at terminal X12 = Multi point probe
Fan control type
266
DryTronic (Fresh air
398
pipe)
Unit without DryTronic
Ext. Hood control
406
Save configuration changes:
Press STEP button to go back into the service main area.
Press FLEXI button.
Sto
Press the STEP button three times for going back to the
main mask.
Switch unit off and on again.
may not flashing in the display.
Final function check.
Funktion
Adjustable
values
no
-1-
/
-4-
/
C2
FI
/
0
1
/
oFF
. must appear on the upper display.
Comments
no = no probe / probe deactivated
-1- = One point single probe (Standard)
-4- = four point multi probe (Option)
C2 = Contactor controlled
FI = Frequency controlled
0= deactivated (standard)
1 = activated (option)
Unit with DryTronic
Off = deactivated (standard)
on
/
On = Ext. hood control activated(At
units with condensation hood
HansDampf Air)
-c-
(Configuration)
Con.
UCF
Sto
Page 4 of 4