SmartCombi™ & ClassicCombi™ Service
Mounting instructions for the WaveClean pumps 215 & 220:
11
Bottom view
Take out fresh air box by removing the screws [11].
Loosen clamp of the pump which has to be changed and
pull hose from the pump.
(A = Cycle pump; B = Drain pump).
Assembling:
The assembly
has to be
exchanged.
Switch on the power and open water tap.
Final function test with the help of the service menu -> WaveClean Test. Close side wall.
B
A
13
carried out in reversed order. The gasket [13] (#211131) between pump and trap should be
Bottom view
Take out fresh air box by removing the screws [12].
A
Remove nuts of the corresponding pump and take out
pump from trap. Note, that water could leak out of the
trap! (A = Cycle pump; B = Drain pump).
Remove wires from the pump.
12
B
Page 3 of 3