Core Temperature Standard Setting; Cooking Chamber Humidity Standard Setting - Henny Penny FlexFusion Spacesaver Operation Manual

Hide thumbs Also See for FlexFusion Spacesaver:
Table of Contents

Advertisement

Description of the unit

3.6.2 Core temperature standard setting

3.6.3 Cooking chamber humidity standard setting

28
Cooking mode
Standard value
(°C (°F))
Steaming
100 (212 )
Combisteaming
150 (302)
Hot air
180 (356)
Regeneration
50 (122 )
The adjustment range for the core temperature depends on the
cooking mode.
Cooking mode
Standard value
(°C (°F))
Steaming
70 (158 )
Combisteaming
70 (158 )
Hot air
70 (158 )
Regeneration
50 (122 )
Cooking chamber humidity setting range depends on the cooking
mode.
Cooking mode
Standard value
(%)
Steaming
100
Combisteaming
90
Hot air
100
Regeneration
100
Operating instructions
Setting range
Change increments
(°C (°F))
(°C (°F))
30 (86 ) - 130
1 (33,8 )
(266)
30 (86 ) - 250
1 (33,8 )
(482)
30 (86 ) - 300
1 (33,8 )
(572)
30 (86 ) - 180
1 (33,8 )
(356)
Setting range
Change increments
(°C (°F))
(°C (°F))
0 (32 ) - 99
1 (33,8 )
(210,2 )
0 (32 ) - 99
1 (33,8 )
(210,2 )
0 (32 ) - 99
1 (33,8 )
(210,2 )
0 (32 ) - 99
1 (33,8 )
(210,2 )
Setting range
Change increments
(%)
(%)
90 - 110
90 - 100 - 110
20 - 100
20 - 40 - 70 - 90 - 100
0 - 100
0 - 25 - 50 - 75 - 100
0 - 100
0 - 25 - 50 - 75 - 100

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flexfusion spacesaver plusFsde 610.610

Table of Contents