RIBBONMINDER
RIBBONMINDER
(From 4–13)
New
Ribbon
Press ENTER to reset
ribbon life to 100%. A
new ribbon must be
installed after setting
the ribbon life to
100%.
New Ribbon
Whenever you install a new ribbon, you must reset the ribbon life to 100%. The
New Ribbon option is where you reset the ribbon display.
Ribbon Action
This option allows you to perform three functions: activate the RibbonMinder ink
consumption display, disable the ink consumption display, and flash a fault
message when the display reaches 0%. Displaying the ribbon ink consumption
allows you to monitor the percentage of ink left in the ribbon. Disabling the ink
consumption monitor removes the visual display, but allows RibbonMinder to
continue monitoring how much ink is left in the ribbon. The Fault option activates
a flash message when the display reaches 0%.
Ribbon Size
The standard ribbon size is 60 yards for the pedestal model, 100 yards for the
cabinet model; these are the factory default settings. You can use the Ribbon
Size option to specify the ribbon length in increments of one yard with a
maximum of 255 yards.
Ribbon Adjust
Enables you to print more or less pages before the display reaches 0%. If the
ribbon normally prints 1000 pages before reaching 0%, configuring the Ribbon
Configuration Menus
Menu
* = Factory default
Ribbon
Ribbon Size
Action
Disable *
Press
Display
crease or
Fault
decrease size.
Pedestal: 60 Yds.*
Cabinet: 100 Yds.*
1 to 255 Yards
Ribbon
Adjust
or
to in-
Press
or
increase or
decrease.
0 *
–99% to 99%
Fault
Action
to
New Ribbon*
Do Nothing