Inlet Needle; Fixed Jet - Stihl MS 240 Instruction Manual

Hide thumbs Also See for MS 240:
Table of Contents

Advertisement

14.4.1 Inlet Needle

– Remove the metering
diaphragm, b 14.4
: Take out the screw (arrow).
2
1
: Pull the inlet control lever (1) with
spindle (2) out of the inlet
needle's groove.
The small spring under the inlet
control lever may pop out.
1
: Remove the inlet needle (1).
– Remove the spring (2). Inspect
and replace if necessary.
MS 240, MS 260, MS 260 C
: If there is an annular indentation
(arrow) on the sealing cone of the
inlet needle, fit a new inlet
needle.
1
: Fit the inlet needle (1).
: Fit the spring (2) in the bore.
1
2
3
2
: Position the inlet control lever (3)
with spindle (2) on the spring's
seat (arrow) first, then slide the
inlet control lever's clevis into the
groove in the inlet needle (1).
Make sure the spring locates on the
control lever's nipple.
– Press the inlet control lever down
and secure it with the screw.
– Check that inlet control lever
moves freely.
– Install the metering diaphragm,
b 14.4

14.4.2 Fixed Jet

2
– Remove the metering
diaphragm,
b 14.4
: Unscrew the fixed jet (1) with a
suitable screwdriver.
Take care not to damage the fixed
jet (1).
– Check the fixed jet (1) and
replace if necessary
– Reassemble in the reverse
sequence.
1