Siemens SINUMERIK 840D sl Function Manual page 396

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Detailed description
2.1 Velocities, traversing ranges, accuracies
For setting the interpolation cycle, see:
References:
/FB3/ Function Manual, Special Functions; Cycle Times (G3)
With a high feedrate (resulting from programmed feedrates and feedrate override), the
maximum path velocity is limited to V
This automatic feedrate limiting can lead to a drop in velocity over several blocks with
programs generated by CAD systems with extremely short blocks.
Example:
Interpolation cycle = 12 ms
N10 G0 X0 Y0; [mm]
N20 G0 X100 Y100; [mm]
⇒ Path length programmed in block = 141.42 mm
⇒ V
The following restriction applies to the minimum path or axis velocity:
The computational resolution is defined via machine data:
MD10200 $MN_INT_INCR_PER_MM (computational resolution for linear positions)
or
MD10210 $MN_INT_INCR_PER_DEG (computational resolution for angular positions):
If V
8
= (141.42 mm/12 ms)
max
is not reached, no traversing is carried out.
min
Basic logic functions: Velocities, Setpoint/Actual Value Systems, Closed-Loop Control (G2)
.
max
0.9 = 10606.6 mm/s = 636.39 m/min
*
Function Manual, 11/2006, 6FC5397-0BP10-2BA0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di slSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840d powerlineSinumerik 840de powerline ... Show all

Table of Contents