MACHINE OPERATIONS AND CONTROLS
9.
On the input display screen displayed on the machine
monitor, input the password and press switch F6.
If a password is set, the input display screen will be indi-
cated on the machine monitor.
REMARK
Contact your Komatsu distributor for details of the method
of setting, changing, or canceling the password.
10. Perform the following inspection on the machine monitor.
1)
Check that the buzzer sounds for approximately 2
seconds and the camera image is displayed.
2)
Check that the following caution lamp and gauge
lights up for approximately 2 seconds.
Hydraulic oil temperature gauge (5)
Engine coolant temperature gauge (6)
Engine oil pressure caution lamp (7)
Charge level caution lamp (8)
Multi-gauge (9)
Fuel gauge (10)
Speed range display (11)
If any caution lamp does not light up or the buzzer does not sound, there is probably a failure in the
machine monitor, so ask your Komatsu distributor for repair.
3)
Check that the screen changes to the gear shift mode
display screen in approximately 2 seconds, and then it
changes to the standard screen.
Hydraulic oil temperature gauge (5)
Engine coolant temperature gauge (6)
Multi-gauge (9)
Fuel gauge (10)
Speed range display (11)
DEF level gauge (12)
DEF level caution lamp (13)
3-186