Komatsu D61EX-24 Operation & Maintenance Manual page 205

Bulldozer
Table of Contents

Advertisement

MACHINE OPERATIONS AND CONTROLS
METHOD FOR CHECKING OIL LEVEL IN HYDRAULIC TANK, ADDING OIL
Immediately after the engine is stopped, its parts and oil are still very hot and may cause burn in-
jury. Wait for the temperature to go down, and then start the work.
When the oil filler cap is removed, oil may spout out. After stopping the engine, wait for the oil tem-
perature to go down, turn the cap slowly to release the internal pressure, then remove the cap with
care.
NOTICE
Do not add oil above H line. It may damage the oil circuit and cause the oil to spurt out.
Set the work equipment to the posture shown in the figure be-
fore checking hydraulic oil level or adding oil.
1.
Place the machine on a level ground and lower the work equipment to the ground.
If the machine is inclining, make it level.
2.
Stop the engine.
3.
Wait for approximately 5 minutes, and then open the hydraulic tank inspection cover at the rear left of the
machine.
4.
Check the oil level with sight gauge (G).
When the oil level is between H and L marks on sight
gauge (G)
The oil level is proper. Close the hydraulic tank in-
spection cover.
3-154
k
k
WARNING
OPERATION

Advertisement

Table of Contents
loading

This manual is also suitable for:

D61px-24