Komatsu D61EX-24 Operation & Maintenance Manual page 186

Bulldozer
Table of Contents

Advertisement

OPERATION
Komatsu Closed Crankcase Ventilation (KCCV)
KCCV is a device to clean the gas discharged from the engine
crankcase with the filter element and return it to the engine air
intake system.
NOTICE
The KCCV filter element needs to be replaced every
2000 hours.
If the engine is operated without KCCV filter element
or if a filter element other than the Komatsu genuine
element is used, the engine sucks oil and foreign ma-
terial which can cause a failure. Always install Komat-
su genuine KCCV filter element.
The filter element cannot be flushed. Never reuse the
filter element since it can cause a performance decre-
ment of engine, and it result in a failure even if it is
cleaned.
EXPLANATION OF COMPONENTS