Komatsu D61EX-24 Operation & Maintenance Manual page 185

Bulldozer
Table of Contents

Advertisement

EXPLANATION OF COMPONENTS
2.
Select "Regeneration Disable" and then press switch F6,
and the regeneration stops.
REMARK
The regeneration performed to protect the system may not
be stopped, but this is not a failure.
PROCEDURE FOR CANCEL OF AFTERTREATMENT DEVICES REGENERATION
DISABLE SETTING
When canceling the regeneration disable, move the machine to a safe place and check that there is no
person or combustible matter around the machine, and start the cancel operation.
1.
When switch F6 is pressed on the standard screen, the
"Aftertreatment Devices Regeneration" screen is dis-
played.
(If the "Aftertreatment Devices Regeneration" screen is not
displayed, display it by operating switches F1 and F2.)
2.
Select "Cancel of Regeneration Disable" and press switch
F6, and the regeneration disable is canceled.
If soot accumulation level (4) is lit 3 or more, the regenera-
tion is started automatically.
REMARK
When performing the cancel of regeneration disable,
set the parking brake lever and work equipment lock
lever to LOCK position and set the fuel control dial to
Low idle (MIN) position, then perform the cancel of re-
generation disable.
The regeneration disable setting is also canceled by
turning the starting switch to OFF position to stop the
engine.