4 IQ-SENSE
Order number
6ES7138-4GA00-0AB0
Features
The 4 IQ-SENSE has the following features:
• Connection of sensors with IQ-SENSE
example, reflex sensors, diffuse sensors, and laser sensors.
• You can connect up to 4 sensors. Each sensor requires a two-wire cable.
• Excess gain and monitoring
• Parameterizable time functions, switching hysteresis, synchronization groups
• Sensitivity and distance values can be specified (IntelliTeach using the
"IQ-SENSE Opto" FB)
• Teach-in
• Module can be removed and inserted during operation (reboot the teach-in
using the "IQ-SENSE Opto" function block or the switch on the sensor)
• Sensors can be removed and inserted during operation (automatic
reparameterization)
• Supports sensors with alignment tool
• The 4 IQ-SENSE is a single-width (15 mm) electronic module that can be used
with the following terminal modules:
– TM-E15S24-01, TM-E15C24-01 and TM-E15N24-01
– TM-E15S26-A1, TM-E15C26-A1 and TM-E15N26-A1
Parameter assignment
You set the parameters for the 4 IQ-SENSE using the STEP 7 parameter
assignment software.
With STEP 7 as of V5.1, ServicePack 3
Contained in the hardware catalog of
HWCONFIG. A DDB file is not required.
14-2
, photoelectric proximity switches: for
R
Configuration rules
With STEP 7 as of V5.0, ServicePack 3 or
other configuration software
IM151-1 BASIC: DDB file SIEM80F3.GSx as
of 09/02 (as of V1.0)
IM151-1 STANDARD: DDB file
SIEM806A.GSx as of 10/01 (as of V1.10)
IM151-1 FO STANDARD: DDB file
SIEM806B.GSx as of 10/01 (as of V1.5)
IM151-1 HIGH FEATURE: DDB file
SIR380E0.GSx as of 12/01 (as of V1.0)