Technical specifications
Dimensions and weight
Dimensions W H D
Weight
Data for specific modules
Supports clocked operation
Number of outputs
Cable length
•
Unshielded
•
Shielded
Voltages, currents, potentials
Rated supply voltage L+
(from the power module)
Reverse polarity protection
Current per channel
•
Up to 50 °C
•
Up to 60 °C
Isolation
•
Between the channels
•
Between channels and
backplane bus
•
Between the channels
and supply voltage
•
Between the supply
voltage and backplane
bus
Permissible potential
difference
•
Between the supply
voltage and backplane
bus
•
Between channels and
backplane bus
•
Between the channels
and supply voltage
Insulation tested
•
Between the supply
voltage and backplane
bus
•
Between channels and
backplane bus
ET 200S Distributed I/O System
EWA-4NEB780602402-09
15 81 52 (mm)
Approx. 50 g
No
2
Max. 600 m
Max. 1000 m
24 VDC
Yes
Max. 5 A
Max. 4 A
Yes
Yes
Yes
Yes
75 VDC, 60 VAC
240 VAC
240 VAC
500 VDC
2500 VDC
Digital Electronic Modules
•
Between the channels
and supply voltage
Current consumption
•
From the power supply
L+
•
From the backplane bus Max. 10 mA
Power dissipation of the
module
Status, interrupts, diagnostics
Status display
Diagnostic functions
Data for selecting an actuator
Output current
•
Continuous thermal
current
•
Min. load current
Connecting two outputs in
parallel
•
For redundant triggering
of a load
•
To increase
performance
Control of a digital input
Switch rate
•
For resistive load
•
With inductive load
•
For lamp load
Limitation (internal) of the
voltage induced on circuit
interruption
Short-circuit protection of
1)
output
1) The relay outputs must be protected by means
of an external safety fuse (6 A,
quick-response).
When installing in a hazardous area, only
remove the fuse using a suitable tool in
accordance with the National Electric Code
(NEC) if the module is not in a potentially
explosive area.
2500 VDC
Max. 30 mA
Typ. 0.6 W
Green LEDs per
channel
No
Max. 5 A
8 mA
No
No
Yes
2 Hz
0.5 Hz
2 Hz
No
No
12-85