Siemens SIMATIC ET 200SP System Manual page 33

Distributed i/o system
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

System overview
3.4 Components
Accessories of the SIMATIC ET 200SP motor starters
Table 3- 4
SIMATIC ET 200SP motor starter accessories
Accessories
3DI/LC module
Mechanical bracket for
BaseUnit
Infeed bus cover
Fan
32
The optional 3DI/LC module has three digital inputs and one
LC input. For reasons of operational safety, input LC is per-
manently set to manual local mode. By parameterizing the
inputs DI1 - DI3 with motor CLOCKWISE or motor
COUNTER-CLOCKWISE, you can control the motor in
manual local mode.
The functions of the 3DI/LC module are not relevant to func-
tional safety.
Detailed information on the functions when using a 3DI/LC
module can be found in the Manual
(https://support.industry.siemens.com/cs/ww/en/view/10947
9973).
Use the mechanical bracket for additional fixing of the motor
starter. You can use the mechanical bracket on 7.5 mm and
15 mm mounting rails.
For finger-safe termination of the infeed bus, use the cover.
You can use the motor starter at higher ambient tempera-
tures if a fan is installed.
Function
Figure
Distributed I/O system
System Manual, 09/2019, A5E03576849-AJ