TWIN end sleeves for the cables of the I/O modules' push-in terminals
Due to the space required by TWIN end sleeves with 0.75 mm
ensure a correct angle for the cable arrangement when crimping the TWIN end sleeve so
that the cables are optimally arranged.
Figure 6-4
Wiring rules for motor starters
Wiring rules for ...
Permitted cable cross-sections of solid
cables (Cu)
Permitted cable
Without end
cross-sections of
sleeve
flexible cables (Cu)
With end sleeve
With end sleeve
(with plastic
sleeve)
Stripping length of the wires
End sleeves according to DIN 46228
with plastic sleeve
Safety standards for fail-safe motor starters
Fail-safe motor starters fulfill the following standards under certain conditions:
● PL e/Cat. 4 according to EN ISO 13849-1
● Safety Integrity Level SILCL3 acc. to IEC 62061
To fulfill both standards, lay cross-circuit proof and P-cross-circuit proof control cables from
the safe output of a sensor or F-DQ to the safe input of the motor starter, e.g. as a
separately sheathed cable or in a separate cable duct.
Distributed I/O system
System Manual, 09/2019, A5E03576849-AJ
Cross-section of the terminal compartment
Crimping TWIN end sleeves at the correct angle
TWIN end sleeves
L1(L), L2(N), L3,
PE
1 to 6 mm
2
AWG: 18 to 10
1 to 6 mm
2
AWG: 18 to 10
1 to 6 mm
2
AWG: 18 to 10
1 to 4 mm
2
AWG: 18 to 11
15 mm
15 mm long
T1, T2, T3, PE, 24 V DC, F-DI,
M
0.5 to 2.5 mm
2
AWG: 20 to 12
0.5 to 2.5 mm
2
AWG: 20 to 12
0.5 to 2.5 mm
2
AWG: 20 to 12
0.5 to 1.5 mm
2
AWG: 20 to 16
10 mm
10 mm long
6.6 Wiring rules
cross-section, you must
2
DI1 ... DI3, LC, M, 24 V
OUT
0.2 to 1.5 mm
2
AWG: 24 to 16
0.2 to 1.5 mm
2
AWG: 24 to 16
0.25 to 1.5 mm
2
AWG: 24 to 16
0.25 to 0.75 mm
2
AWG: 24 to 18
8 mm
8 mm long
Wiring
99