2.3 Power Supply Troubleshooting
Procedure 2
Error Code Check
If the power supply microprocessor detects a malfunction, it indicates the error code as
shown below.
The error code begins with the least significant digit.
Error code
Error code
Where Error occurs
1*h
Adaptor
(AC Adaptor, DS)
2*h
The 1st battery
3*h
The 2nd Battery
4*h
S3V output
5*h
1R5 -C1V output
6*h
1R8 -C1V output
7*h
PPV output
8*h
PGV output
9*h
E5V output
A*h
E3V output
B*h
1R2 -P1V output
C*h
PTV output
D*h
1R25-P1V output
E*h
2R5 -E2V output
F*h
TECRA M1 Maintenance Manual (960 -436)
AC Adaptor is not connected.
Error code begins with : 0x10
Error code ends with
The 1st Battery is not connected.
Error code begins with : 0x20
Error code ends with
The 2nd Battery is not connected.
Error code begins with : 0x30
Error code ends with
Operating Power ON
Error code begins with : 0x40
Error code ends with : 0xDF
2 Troubleshooting Procedures
: 0x1F
: 0x2F
: 0x3F
2-7