F30706
SI Motion P2: SAM/SBR limit exceeded
Response
NONE
Acknowledg‐
IMMEDIATELY (POWER ON)
ment
Explanation
After the initiation of STOP B (SS1) or STOP C (SS2), the speed has exceeded the selected tolerance value.
The drive is stopped with message C30700 "SI Motion P2: STOP A initiated".
Remedy
Check the braking behavior and if required, adapt the parameterization of the "SAM" or "SBR" function.
This message can only be acknowledged in the acceptance test mode without POWER ON via PROFIsafe.
11.4

Safety PLC alarms

400253
PLC-STOP due to an SPL system error
Explanation
After an interruption in the communications between NCK and PLC regarding the SPL crosswise data com‐
parison, the PLC was switched into the STOP state with a delay of 5 s.
Response
Alarm display
Remedy
Do not start the SPL anymore. Check the system components (PLC must have the correct version of FB15
and have DB18).
Program con‐
Remove the error. Switch control system OFF and ON again.
tinuation
400254
Checksum error occurred: %1 parameter: %1 = reference to the code section or table
Explanation
Checksum error in safety-related code or safety-related data. The safety monitoring functions (Safety Inte‐
grated) in the PLC could be corrupted.
Response
Alarm display
Remedy
Switch off the control and switch on again. If this fault occurs again, contact the service department. In
addition perform a general reset for NC, PLC and reload the archive.
Program con‐
Switch control system OFF and ON again.
tinuation
400551
Error on the MPI/DP bus
Explanation
I/O bus error detected
Response
Alarm display
Remedy
Check the I/O, resolve I/O errors
Program con‐
Internal
tinuation
400552
Error on the DP bus
Explanation
I/O bus error detected
Response
Alarm display
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
Diagnostics
11.4 Safety PLC alarms
745