Data descriptions
9.1 Machine data for SINUMERIK 840D sl
Number
10092
INFO_CROSSCHECK_CYCLE_TIME
10093
INFO_NUM_SAFE_FILE_ACCESS
10094
SAFE_ALARM_SUPPRESS_LEVEL
10095
SAFE_MODE_MASK, bit 1
10096
SAFE_DIAGNOSIS_MASK
10097
SAFE_SPL_STOP_MODE
10098
PROFISAFE_IPO_TIME_RATIO
10099
INFO_PROFISAFE_CYCLE_TIME
10200
INT_INCR_PER_MM
10210
INT_INCR_PER_DEG
10385
PROFISAFE_MASTER_ADRESS
10386
PROFISAFE_IN_ADRESS
10387
PROFISAFE_OUT_ADRESS
10388
PROFISAFE_IN_ASSIGN
10389
PROFISAFE_OUT_ASSIGN
10393
SAFE_DRIVE_LOGIC_ADDRESS
11411
ENABLE_ALARM_MASK
11415
SUPPRESS_ALARM_MASK_2
11500
PREVENT_SYNACT_LOCK
11602
ASUP_START_MASK
11604
ASUB_START_PRIO_LEVEL
13300
PROFISAFE_IN_FILTER
13301
PROFISAFE_OUT_FILTER
13302
PROFISAFE_IN_ENABLE_MASK
13303
PROFISAFE_OUT_ENABLE_MASK
13304
PROFISAFE_IN_SUBS_ENAB_MASK
13305
PROFISAFE_IN_SUBS
13307
PROFISAFE_IPO_RESERVE
13308
PROFISAFE_IN_NAME
13309
PROFISAFE_OUT_NAME
13310
SAFE_SPL_START_TIMEOUT
13312
SAFE_SPL_USER_DATA
312
Identifier
Name
Displays the clock cycle time for a crosswise
data comparison
Number of SPL file access operations
Alarm suppression level
Safety Integrated operating modes
Safety Integrated diagnostic functions
Stop response for SPL errors
Factor PROFIsafe communications clock cy‐
cle time
PROFIsafe communications clock cycle time
Computational resolution for linear positions
see /FB1/, G2
Computational resolution for angular positions
see /FB1/, G2
PROFIsafe address of the PROFIsafe master
module
PROFIsafe address of an input module
PROFIsafe address of a PROFIsafe output
module
Input assignment, $A_INSE to PROFIsafe in‐
put module
Output assignment, $A_OUTSE to PROFI‐
safe module
Logical drive addresses, SI
Activation of alarms
Suppress alarm outputs
Protected synchronized actions
Ignore stop conditions for ASUB
Priorities as of which ASUP_START_MASK
takes effect
F-net data filter IN
F-net data filter OUT
Enable screen of the connections to PROFI‐
safe input modules
Enable screen form of the connections to
PROFIsafe output modules
Activation of the substitute value output for
PROFIsafe input modules
Substitute values for passive connections to
PROFIsafe input modules
Number of IPO clock cycles without PROFI‐
safe calculations
Name of the PROFIsafe input module
Name of the PROFIsafe output module
Delay, display Alarm 27097
User SPL data is changed
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
Checksums MD
--
--
--
NCK[2], NCK[0]
--
NCK[0]
NCK[0]
--
--
--
NCK[0]
NCK[0]
NCK[0]
NCK[0]
NCK[0]
AX[2]
--
--
--
--
--
NCK[0]
NCK[0]
NCK[2]
NCK[2]
NCK[2]
NCK[0]
--
--
--
--
NCK[1]
Safety Integrated