11.2 NCK safety alarms for SINUMERIK 840D sl
15189
Channel %1 Block %2 Error executing SAFE.SPF
Parameter
%1 = channel number
%2 = block number, label
Explanation
When processing the NC initialization program for Safety Integrated /_N_CST_DIR/_N_SAFE_SPF an error
has occurred. Alarm 15189 is output together with the alarm that describes the cause of the error. The function
is activated with MD20108 $MC_PROG_EVENT_MASK, bit 5=1.
Response
NC stop for alarm
Remedy
Carry out an NCK reset (warm restart)
Program con‐
Switch control system OFF and ON again.
tinuation
15420
Channel %1 Block %2 Instruction in actual mode not allowed
Parameter
%1 = channel number
%2 = block number, label
Explanation
The alarm is output in the following situations:
● When executing an INI file or definition file (macro or GUD), the interpreter has identified an illegal
instruction (e.g. traversing command).
● In a GUD file, access protection to a machine data with REDEF is to be changed, although an ACCESS
file (_N_SACCESS_DEF, _N_MACCESS_DEF, _NUACCESS_DEF) is available. Access rights for
machine data may then only be changed using one of the ACCESS files with REDEF.
● When executing the safety initialization program /_N_CST_DIR/_N_SAFE_SPF, due to the reduced
language scope that was configured for the purpose, an illegal statement was identified.
Response
Interpreter stop
NC start disable in this channel
Interface signals are set
Alarm display
Remedy
● Correct INI, GUD, or macro file
● Correct part program
Program con‐
Clear the alarm with the RESET key. Restart the part program.
tinuation
16964
Channel %1 executing init blocks not fully completed
Parameter
%1 = channel number
Explanation
When booting, init blocks are executed. These ensure that the control is correctly initialized. The alarm is
output if the execution was not able to be correctly ended (generally due to an already existing alarm).
Response
Alarm display
Remedy
Remove the existing alarm.
Program con‐
Switch control system OFF and ON again.
tinuation
598
Function Manual, 12/2017, 6FC5397-4BP40-6BA1