Siemens SINUMERIK 840D sl Function Manual page 700

Safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Diagnostics
11.3 Safety messages for SINAMICS S120
N01620 (F, A) SI P1 (CU): Safe Torque Off active
Explanation
The "Safe Torque Off" (STO) function of the basis functions has been selected on the Control Unit (CU) via
the input terminal and is active.
Note:
This message does not result in a safety stop response.
For STO selection using the Extended Functions, this message is not output.
Remedy
Not necessary
Response for
OFF2
F
Acknowledg‐
IMMEDIATELY (POWER ON)
ment for F
Response for
NONE
A:
Acknowledg‐
NONE
ment for A
N01621 (F, A) SI P1 (CU): Safe Stop 1 active
Response
NONE
Acknowledg‐
NONE
ment
Explanation
The "Safe Stop 1" (SS1) function has been selected on the Control Unit (CU) and is active.
Note:
This message does not result in a safety stop response.
Remedy
Not necessary
Response for
OFF3
F
Acknowledg‐
IMMEDIATELY (POWER ON)
ment for F
Response for
NONE
A:
Acknowledg‐
NONE
ment for A
F01625
SI P1 (CU): Sign-of-life error in the safety data
Response
OFF2
Acknowledg‐
IMMEDIATELY (POWER ON)
ment
700
Function Manual, 12/2017, 6FC5397-4BP40-6BA1