Siemens SINUMERIK 840D sl Function Manual page 439

Safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

r9711[0...1]
SI Motion diagnostics results list 2
Displays result list 2, which led to an error between the two monitoring channels
for a crosswise data comparison.
[0]: Result list second channel
[1]: Result list, drive
Bit 00 actual value > upper limit SCA1+ (SN1+)
1 signal: Yes, 0 signal: No
Bit 01 actual value > lower limit SCA1+ (SN1+)
1 signal: Yes, 0 signal: No
Bit 02 actual value > upper limit SCA1+ (SN1-)
1 signal: Yes, 0 signal: No
Bit 03 actual value > lower limit SCA1- (SN1-)
1 signal: Yes, 0 signal: No
Bit 04 actual value > upper limit SCA2+ (SN2+)
1 signal: Yes, 0 signal: No
Bit 05 actual value > lower limit SCA2+ (SN2+)
1 signal: Yes, 0 signal: No
Bit 06 actual value > upper limit SCA2- (SN2-)
1 signal: Yes, 0 signal: No
Bit 07 actual value > lower limit SCA2- (SN2-)
1 signal: Yes, 0 signal: No
Bit 08 actual value > upper limit SCA3+ (SN3+)
1 signal: Yes, 0 signal: No
Bit 09 actual value > lower limit SCA3+ (SN3+)
1 signal: Yes, 0 signal: No
Bit 10 actual value > upper limit SCA3- (SN3-)
1 signal: Yes, 0 signal: No
Bit 11 actual value > lower limit SCA3- (SN3-)
1 signal: Yes, 0 signal: No
Bit 12 actual value > upper limit SCA4+ (SN4+)
1 signal: Yes, 0 signal: No
Bit 13 actual value > lower limit SCA4+ (SN4+)
1 signal: Yes, 0 signal: No
Bit 14 actual value > upper limit SCA4- (SN4-)
1 signal: Yes, 0 signal: No
Bit 15 actual value > lower limit SCA4- (SN4-)
1 signal: Yes, 0 signal: No
Bit 16 actual value > upper limit SSM+ (n
1 signal: Yes, 0 signal: No
Bit 17 actual value > lower limit SSM+ (n
1 signal: Yes, 0 signal: No
Bit 18 actual value > upper limit SSM- (n
1 signal: Yes, 0 signal: No
Bit 19 actual value > lower limit SSM- (n
1 signal: Yes, 0 signal: No
Bit 20 actual value > upper limit modulo
1 signal: Yes, 0 signal: No
Bit 21 actual value > lower limit modulo
1 signal: Yes, 0 signal: No
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
+)
x
+)
x
-)
x
-)
x
Data descriptions
9.2 Parameters for SINAMICS S120
Checksum:
Protection level:
No
3
439

Advertisement

Table of Contents
loading

Table of Contents