13309
Meaning:
corresponds with ...
Additional reference
13310
MD number
Default value 20.
Change becomes effective after: POWER ON
Data type: DOUBLE
Meaning:
corresponds with ...
Additional reference
13312
MD number
Default value 0
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional reference
13316
MD number
Default value -
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional reference
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
$MN_PROFISAFE_OUT_NAME[0...47]
Every PROFIsafe output module can be assigned a symbolic name. If a name is assigned,
this is displayed in the alarm text instead of the PROFIsafe address.
$MN_SAFE_SPL_START_TIMEOUT
Delay, display Alarm 27097
Min. input limit: 1.
After the control has booted, after the time has expired, Alarm 27097 is displayed if there was
no SPL start.
$MN_SAFE_SPL_USER_DATA[0...3]
User data
Min. input limit: 0x0
User data is used to save user-specific information.
Using crosswise data comparison between the NCK and PLC, this data is monitored for
changes. Changes to this data are identified by the checksum calculation and signaled with
alarm 27071.
The data must match the corresponding PLC data (DB18.DBD 256 - 268). Discrepancies
between the NCK and PLC lead to the parameterized Stops (STOP D or STOP E) being
initiated and are displayed using Alarm 27090.
$MN_SAFE_GLOB_CFIG_CHANGE_DATA[0...6]
Date/time of the last change SI-NCK-MD
Min. input limit: -
Display data:
Date and time of the last configuration change of safety-related NCK machine data.
Changes made to the machine data that are calculated into the checksums MD13318
$MN_SAFE_GLOB_ACT_CHECKSUM are recorded.
9.1 Machine data for SINUMERIK 840D sl
Protection level: 7/2
Protection level: 7/2
Protection level: 7/-
Data descriptions
Max. input limit: 60.
Unit: s
Max. input limit: 0xFFFFFFFF
Unit: -
Max. input limit: -
Unit: -