Data descriptions
9.2 Parameters for SINAMICS S120
r9871
SI common functions (Motor Module)
Displays the Safety Integrated monitoring functions supported on the Control Unit
and Motor Module.
The Motor Module/Hydraulic Module determines this display.
Bit 00: STO via terminals is supported
1 signal: Yes, 0 signal: No
Bit 01: SBC is supported
1 signal: Yes, 0 signal: No
Bit 02: Extended Functions supported (p9501 > 0)
1 signal: Yes, 0 signal: No
Bit 03: SS1 supported
1 signal: Yes, 0 signal: No
Bit 08: Safe Brake Adapter supported
1 signal: Yes, 0 signal: No
Bit 13: ESR delay of the pulse cancellation supported
1 signal: Yes, 0 signal: No
See also: r9771
Unit:
Default value:
-
-
460
Minimum value:
Maximum value:
-
-
Checksum:
Protection level:
No
3
Data type:
Effectiveness:
Unsigned32
-
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
Safety Integrated