20108
MD number
Default value (0x0, 0x0,...)
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional reference
20192
MD number
Default value (0x0, 0x0,...)
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional reference
Safety Integrated
Function Manual, 12/2017, 6FC5397-4BP40-6BA1
$MC_PROG_EVENT_MASK
Event-controlled program call
Min. input limit: 0
Parameterizes the event where the user program set with MD11620
$MN_PROG_EVENT_NAME (default setting: _N_PROG_EVENT_SPF) is implicitly called:
Bit 0 = 1: Part program start
Bit 1 = 1: Part program end
Bit 2 = 1: Operator panel reset
Bit 3 = 1: Booting
Bit 4 = 1: Reserved
Bit 5 = 1: Safety program during power-up
The user program is called using the following search path:
1. /_N_CUS_DIR/_NPROG_EVENT_SPF
2. /_N_CMA_DIR/_NPROG_EVENT_SPF
3. /_N_CST_DIR/_NPROG_EVENT_SPF
The safety program must be available at the following location:
1. _N_CST_DIR/_N_SAFE_SPF
In addition, after the action blocks, the user program set using MD11620
$MN_PROG_EVENT_NAME is automatically started via MD11450
$MN_SEARCH_RUN_MODE bit 1, independent of the settings in this machine data.
$MC_PROG_EVENT_IGN_PROG_STATE
Do not display the execution of the prog events on the OPI
Min. input limit: 0
Event-controlled program calls (prog events) can be influenced regarding their behavior at the
OPI interface. The variables progStatus and chanStatus remain uninfluenced in spite of the
active prog event processing - and stay at the old value. As a consequence, the prog event
processing can be hidden from the HMI.
Bit 0 = 1: Reserved bit with effect
Bit 1 = 1: Prog event after part program end does not change progStatus and chanStatus
Bit 2 = 1: Prog event after operator panel reset does not change progStatus and chanStatus
Bit 3 = 1: Prog event after booting does not change progStatus and chanStatus
Bit 4 = 1: Reserved
Bit 5 = 1: Safety prog event when booting does not change progStatus and chanStatus
9.1 Machine data for SINUMERIK 840D sl
Protection level: 7/2
Protection level: 7/2
Data descriptions
Max. input limit: 0x3F
Unit: -
Max. input limit: 0x3F
Unit: -