Acceleration and Deceleration Characteristics

This section explains the acceleration and deceleration characteristics of the Inverter.

Setting Acceleration and Deceleration Times

Acceleration time indicates the time taken for the output frequency to climb from 0% to 100%. Deceleration
time indicates the time taken for the output frequency to reduce to 0%. The factory setting of the acceleration
time is C1-01, and the factory setting of the deceleration time is C1-02.
Related Parameters
Constant
Number
C1-01
C1-02
C1-03
C1-04
C1-05
C1-06
C1-07
C1-08
C1-11
-10
6
Name
Description
Display
Acceleration time 1 Sets the acceleration time to accelerate
from 0 to the maximum output fre-
Accel Time 1
quency, in 1-second units.
Deceleration time 1 Sets the deceleration time to deceler-
ate from the maximum output fre-
Decel Time 1
quency to 0, in 1-second units.
Acceleration time 2 The acceleration time when the multi-
function input "accel/decel time 1" is
Accel Time 2
set to on.
Deceleration time 2 The deceleration time when the multi-
function input "accel/decel time 1" is
Decel Time 2
set to on.
Acceleration time 3 The acceleration time when the multi-
function input "accel/decel time 2" is
Accel Time 3
set to on.
Deceleration time 3 The deceleration time when the multi-
function input "accel/decel time 2" is
Decel Time 3
set to on.
Acceleration time 4 The acceleration time when the multi-
function input "accel/decel time 1"
Accel Time 4
and "accel/decel time 2" are set to on.
Deceleration time 4 The deceleration time when the multi-
function input "accel/decel time 1"
Decel Time 4
and "accel/decel time 2" are set to on.
Accel/decel time
Sets the frequency for automatic
switching fre-
acceleration/deceleration switching.
quency
Below set frequency:
Accel/decel time 4
Above set frequency:
Accel/decel time 1
Acc/Dec SW Freq
The multi-function input "accel/decel
time 1" or "accel/decel time 2" take
priority.
Control
Change
Methods
Fac-
during
Setting
tory
Open-
Range
Opera-
Setting
loop
tion
Vector
60.0 s
Yes
Q
120.0 s
Yes
Q
60.0 s
Yes
A
120.0 s
Yes
A
0.0 to
6000.0
60.0 s
No
A
120.0 s
No
A
60.0 s
No
A
120.0 s
No
A
0.0 to
0.00%
No
A
100.00
MEMOBUS
Register
Flux
Vector
Q
240H
Q
241H
A
242H
A
243H
A
244H
A
245H
A
246H
A
247H
A
24AH