Time Chart
The following figure shows the frequency characteristics when L3-01 is set to 1.
Setting Precautions
If the motor capacity is small compared to the Inverter capacity, or if the motor is operated using the fac-
tory settings, resulting in the motor stalling, lower the set value of L3-02.
If using the motor in the constant output range, L3-02 will be automatically lowered to prevent stalling.
L3-03 is the limit value to prevent the stall prevention level in the constant output range from being
reduced more than necessary.
Set the constants as a percent taking the Inverter rated voltage to be 100%.
Stall prevention level during
acceleration
-14
6
Output current
Stall level during
acceleration
Output frequency
Output frequency is controlled
to prevent the motor stalling.
Fig 6.10 Time Chart for Stall Prevention During Acceleration
E1-06
Base Frequency (FA)
Fig 6.11 Stall Prevention Level and Limit During Acceleration
Time
Time
L3-02 (Stall Prevention Level during
Acceleration)
L3-02 x L3-03 (Stall Prevention Limit during
Acceleration)
Output frequency