Name
Constant
Number
Display
Speed search wait time
(current detection or
speed calculation)
b3-05
Search Delay
Output current 1
during speed search
b3-06
Srch Im Lvl1
Output current 2
during speed search
b3-07
Srch Im Lvl2
Speed search detection
compensation gain
(speed calculation)
b3-10
Srch Detect Comp
Speed search method
switching level
b3-11
Srch Mthd Sw Lvl
Setting
Description
Range
Sets the magnetic contactor
operating delay time when
there is a magnetic contactor on
the output side of the Inverter.
0.0 to
When a speed search is per-
formed after recovering from a
momentary power loss, the
search operation is delayed by
the time set here.
Sets the output current during
the first half of speed search as
a coefficient to the motor rated
current (E2-01). (Only for exci-
tation search) Increase the set
0.0 to
value if the search speed
becomes extremely slow at the
speed search after the motor
has been base-blocked for a
long time of period such as the
speed search at startup.
Sets the output current during
the last half of speed search as a
coefficient to the motor no-load
current (E2-03). The multipli-
cation of motor no-load current
and set coefficient is limited to
the motor rated current (E2-01)
0.0 to
inside the Inverter. (Only for
excitation search) Increase the
set value if the search speed
becomes extremely slow at the
speed search after the motor
has been base-blocked for a
long time of period such as the
speed search at startup.
Operation restarts at a speed
obtained by multiplying the
speed from the speed search by
the compensation gain (excita-
tion search only.)
1.00 to
Increase this setting if overvolt-
ages of cells occur when a
speed search is performed after
a long baseblock, for example,
in searches at startup.
On speed calculation, the
search method is automatically
0.5 to
switched according to the
100.0
motor residential voltage. Set
the switching level.
Change
Factory
during
Open-
Setting
Operation
loop
Vector
0.2 s
No
A
20.0
0.5
No
A
1.0
1.5
No
A
3.0
1.05
No
A
1.50
5.0%
No
A
Continuing Operation
Control
Methods
MEMOBUS
Register
Flux
Vector
A
1C4H
A
1C5H
A
1C6H
No
1C9H
A
1CAH
37