GP 15 Clearing a 092-310 Fault Code (ADC fail)
Procedure
The following NVM locations that are related to 092-310 Fault Code (ADC fail):
NVM location
752-095
ADC Sensor failure
752-096
ADC shutter is kept opened (a failure reported when ADC shutter does not
close)
752-097
ADC shutter is kept closed (a failure reported when ADC shutter does not
open)
752-098
A failure related to Yellow TC (Toner Concentration) patch
752-099
A failure related to Magenta TC (Toner Concentration) patch
752-100
A failure related to Cyan TC (Toner Concentration) patch
752-101
A failure related to Black TC (Toner Concentration) patch
752-102
A failure related to Yellow ADC patch
752-103
A failure related to Magenta ADC patch
752-104
A failure related to Cyan ADC patch
752-105
A failure related to Black ADC patch
752-106
A failure related to Yellow patch density while performing long setup opera-
tion
752-107
A failure related to Magenta patch density while performing long setup
operation
752-108
A failure related to Cyan patch density while performing long setup opera-
tion
752-109
A failure related to Black patch density while performing long setup opera-
tion
752-121
The count of ADC fails
752-094
ADC Sensor failure (a failure reported when the count of ADC related fails
is reached to a specified number of times)
1.
The NVM location 752-121 is incriminated by 1 each time any failures of 752-095 to 752-
109 occurs. When the count of 752-121 exceeds "3", the fault code 092-310 (ADC fail) is
displayed on the UI and the machine stops. The fault code 092-310 can be cancelled by
machine power off/on. After the fault code 092-310 is cleared, the machine will allow print-
ing of 100 more pages and performs ADC setup operations. If there are no ADC related
failures occurring while printing 100 pages, then the machine will be resumed. However,
the count of 752-121 will not be cleared. If there is an ADC related failure occurring while
printing 100 pages, then the machine will display the fault code 092-310, and fault code
092-310 will not be cleared by machine power off/on.
2.
If the toner condition is normal status (i.e. when toner is not empty status): when the count
of NVM value 752-121 exceeds "50", then the machine stops, and the fault code 092-310
cannot be cleared. Then, "1" will be set to the NVM location 752-094.
If toner condition is pre-near status (i.e. order toner status): when the count of 752-121
exceeds "8", then the machine stops, the fault code 92-310 cannot be cleared. Then, "1"
will be set to the NVM location 752-094.
Reversion 4.0
WorkCentre 7132
Table 1
Description
When "1" is set to 752-094, the NVM 752-121 needs to be cleared to "0". When, NVM
752-121 is cleared to "0", NVM 752-094 will be automatically cleared to "0". Then, the
fault code 092-310 can be cleared.
However, to resolve the fault code 092-310 completely, you need to find out the cause of any
failure of NVM locations 752-095 to 752-109.