GP 7 Country Code Setting
Purpose
To input country code.
Procedure
1.
Access Diagnostic Routines.
a.
Enter UI Diagnostic Mode.
2.
Select NVM Read Write.
3.
Perform NVM Read/Write on Chain Link 700-165.
0: No customer setting (default)
1: Customer setting for other than North America.
2: Customer setting for North America.
4.
Select Close and Exit.
Change country code at Customer site.
1.
Enter System Administrator mode.
a.
Press Log In/Out button on Control Panel.
b.
Enter (five one's) 11111.
2.
Select System Setting -> Common Settings -> Other Settings.
3.
In the menu, 15. Country to be selected.
This menu shall appear only when Chain-Link 700-840 is set to 1 or 2.
4.
Select Change Settings.
5.
Country menu appears.
6.
Select the country.
7.
Select Save.
8.
Select Close 3 times and Exit.
Reversion 4.0
WorkCentre 7132
GP 8 Firmware Version
Description
This procedure describes how to determine firmware version of machine subsystems that are
administered by Firmware Version designations.
Procedure
Firmware Version of Controller+PS ROM, IOT ROM, Finisher ROM, IIT ROM, ADF ROM,
and FAX ROM
NOTE: If paper size errors occur when attempting to print reports, check that NVM location
700-397 is set for the appropriate paper size (44 = 8.5 x 11 in.; 5 = A4) (refer to NVM Read/
Write).
1.
Press the Machine Status button on the Control Panel.
2.
Select Billing Meter/Print Report tab on the display.
3.
Select Print Report/List.
4.
Select Print Mode Settings.
5.
Select Settings List - Common Items.
6.
Press the Start button.
NOTE: Page 1 of the report will list Firmware Version of Controller+PS ROM, IOT ROM,
Finisher ROM, IIT ROM, ADF ROM, and FAX ROM
Firmware Version of Duplex, and TTM/2TM
NOTE: Obtaining the Firmware Level for the Duplex Module, and the TTM (Tandem Tray Mod-
ule)/ 2TM (2 Tray Module) requires reading two NVM locations, adding a decimal point behind
the first read, adding a leading zero if the second read is a single digit, and combining the sec-
ond read behind the decimal point to formulate a Firmware Level.
1.
Enter UI Diagnostic Mode.
2.
Select Maintenance/Diagnostics.
3.
Select NVM Read/Write.
4.
To check Duplex go to step 5.
To check TTM/2TM go to 6.
5.
Perform following to check Duplex.
a.
Enter 742-227 using number keypad and select Confirm/Change.
b.
Record the Current Value. Place a decimal point after the value.
c.
Select Cancel.
d.
Enter 742-228 using number keypad and select Confirm/Change.
e.
Record the Current Value. If Current Value is a single digit, add a leading zero and
record behind decimal from first read. This is the Duplex Firmware Version.
f.
Select Cancel as required to exit or proceed to next step.
6.
Perform following to check TTM/2TM.
a.
Enter 742-229 using number keypad and select Confirm/Change.
b.
Record the Current Value. Place a decimal point after the value.
c.
Select Cancel.
d.
Enter 742-230 using number keypad and select Confirm/Change.
January 2007
6-207
General procedures information
GP 7, GP 8