Chain-Link NVM Name
825-018
Line Cutoff detection For Ch1
825-019
Line Cutoff detection For Ch2
825-020
Line Cutoff detection For Ch3
825-021
Line Cutoff detection For Ch4
825-022
Line Cutoff detection For Ch5
825-024
To determine fallback redial from G4 to G3
when CAUSE #42 and #65 were received
in ISDN communication.
825-025
Process to determine continuity in the
Transmitter when RTN was received. This
is meant for ZZF.
825-033
Timing of tone detection before dialing
(PBX). The time required to detect the
Tone before dialing. For PBX.
825-046
PB Send Level Ch0
825-047
PB Send Level Ch1
825-048
PB Send Level Ch2
825-049
PB Send Level Ch3
825-050
PB Send Level Ch4
825-051
PB Send Level Ch5
825-052
PB Send Level (high-pass - low-pass (dB))
For Ch0
825-053
PB Send Level (high-pass - low-pass (dB))
For Ch1
825-054
PB Send Level (high-pass - low-pass (dB))
For Ch2
825-055
PB Send Level (high-pass - low-pass (dB))
For Ch3
825-056
PB Send Level (high-pass - low-pass (dB))
For Ch4
825-057
PB Send Level (high-pass - low-pass (dB))
For Ch5
General procedures information
Controller & Fax NVM List
Table 11 NVM 825 FAX Service
Setup
Range
Initial Value
Read/Write
0~1
1: Detect disconnec-
Read/Write
tion
0~1
1: Detect disconnec-
Read/Write
tion
0~1
1: Detect disconnec-
Read/Write
tion
0~1
1: Detect disconnec-
Read/Write
tion
0~1
1: Detect disconnec-
Read/Write
tion
0~1
0 = Fallback Redial
Read/Write
OFF
0~1
0: Continue
Read/Write
0~255
4
Read/Write
0~15
6
Read/Write
0~15
6
Read/Write
0~15
6
Read/Write
0~15
6
Read/Write
0~15
6
Read/Write
0~15
6
Read/Write
0~15
0
Read/Write
0~15
0
Read/Write
0~15
0
Read/Write
0~15
0
Read/Write
0~15
0
Read/Write
0~15
0
Read/Write
January 2007
6-152
Description
0: Do not detect disconnection, 1: Detect disconnection
0: Do not detect disconnection, 1: Detect disconnection
0: Do not detect disconnection, 1: Detect disconnection
0: Do not detect disconnection, 1: Detect disconnection
0: Do not detect disconnection, 1: Detect disconnection
0 = Fallback Redial OFF, 1 = Fallback Redial ON
0: Determine the fallback from the TCF check result and con-
tinue sending. 1: Stop transmission. (The document becomes
eligible for resend)
0 ~ 255 (Sec)
0: 0dBm (0) ~-15: 15dBm step: -1dBm
0: 0dBm (0) ~-15: 15dBm step: -1dBm
0: 0dBm (0) ~-15: 15dBm step: -1dBm
0: 0dBm (0) ~-15: 15dBm step: -1dBm
0: 0dBm (0) ~-15: 15dBm step: -1dBm
0: 0dBm (0) ~-15: 15dBm step: -1dBm
High-pass - Low-pass (dB) 0: 2.0, 1:
2.52:3.0A3:3.5A4:4.0A5:4.5A6:5.0A7:5.5A8:-2.0A9:-1.5A10:-
1.0A11:-0.5A12:0 13:0.5A14:1.0A15:1.5
High-pass - Low-pass (dB) 0: 2.0, 1:
2.52:3.0A3:3.5A4:4.0A5:4.5A6:5.0A7:5.5A8:-2.0A9:-1.5A10:-
1.0A11:-0.5A12:0 13:0.5A14:1.0A15:1.5
High-pass - Low-pass (dB) 0: 2.0, 1:
2.52:3.0A3:3.5A4:4.0A5:4.5A6:5.0A7:5.5A8:-2.0A9:-1.5A10:-
1.0A11:-0.5A12:0 13:0.5A14:1.0A15:1.5
High-pass - Low-pass (dB) 0: 2.0, 1:
2.52:3.0A3:3.5A4:4.0A5:4.5A6:5.0A7:5.5A8:-2.0A9:-1.5A10:-
1.0A11:-0.5A12:0 13:0.5A14:1.0A15:1.5
High-pass - Low-pass (dB) 0: 2.0, 1:
2.52:3.0A3:3.5A4:4.0A5:4.5A6:5.0A7:5.5A8:-2.0A9:-1.5A10:-
1.0A11:-0.5A12:0 13:0.5A14:1.0A15:1.5
High-pass - Low-pass (dB) 0: 2.0,1:
2.52:3.0A3:3.5A4:4.0A5:4.5A6:5.0A7:5.5A8:-2.0A9:-1.5A10:-
1.0A11:-0.5A12:0 13:0.5A14:1.0A15:1.5