Chain-Link Name
005-029
DADF Reg.Motor(Speed4)
005-030
DADF Reg.Motor(Speed5)
005-031
DADF Reg.Motor(Speed6)
005-032
DADF Reg.Motor(Speed7)
005-033
DADF Reg.Motor(Speed8)
005-034
DADF Reg.Motor(Speed9)
005-036
DADF Reg.Motor(Reverse)
005-072
Nip Release Solenoid
005-083
Doc Ready
005-084
Doc Set LED
005-088
Image Area
005-090
Nudger initialize
062-002
IIT Exposure Lamp
062-004
IPS Cooling Fan (Low speed)
062-005
IIT Scan Motor (Scan)
062-006
IIT Scan Motor (Return)
062-014
IPS Cooling Fan (High speed)
062-015
Lamp Cooling Fan
062-017
CCD Cooling Fan
062-086
IIT Image Area
062-091
Exchange To ADF
Reversion 4.0
WorkCentre 7132
Table 4 Output Component Control Codes IIT
Connector Level
Meaning
-
ON for 50sec -> Auto OFF O
-
ON for 50sec -> Auto OFF O
-
ON for 50sec -> Auto OFF O
-
ON for 50sec -> Auto OFF O
-
ON for 50sec -> Auto OFF O
-
ON for 50sec -> Auto OFF O
-
ON for 50sec -> Auto OFF O
L
3sec on
L
Turn ON the Doc Ready
signal.
L
Belt: Turn ON the DOC
SET LED
H
ON for 5sec
-
Performs Nudger Roll ini-
tialization.
L
Turn the Lamp ON for
180sec -> Auto OFF
L
Same as name
Each has 4 phases.
Move it 50mm from cur-
H/L Switching
rent position in Scan
direction -> Auto OFF
Each has 4 phases.
Move it 50mm from cur-
H/L Switching
rent position in Return
direction -> Auto OFF
H
Same as name
H
Same as name
H
Same as name
(Differential) H
IMAGE-AREA Signal Out-
put
L
Turn ON the document
exchange command sig-
nal to the DADF
January 2007
6-191
Multiple Output
Timer Off
Prohibited Items
Remarks
005-026~005-028
005-030~005-036
005-026~005-029
005-031~005-036
005-026~005-030
005-032~005-036
005-026~005-031
005-033~005-036
005-026~005-032
005-034~005-036
005-026~005-033
005-035~005-036
005-026~005-036
O
-
X
-
X(Belt)
-
O(DADF)
O
-
O
-
O
-
Turn it OFF when Stop command is
received before Auto OFF.
O
-
O
062-006
Stop command is not accepted before
Auto OFF.
O
062-005
Stop command is not accepted before
Auto OFF.
O
-
O
-
O
-
X
-
X
-