IIT PF-HFSI/Recycle List
Chain-Link
Name
956-802
IIT Scan
956-803
Lamp ON Time
956-804
Lamp ON Count
956-808
Platen Open/Close Count
(Platen models)
955-806
Document Feed (CVT,
DADF models)
955-807
Document Feed Simp
(CVT, DADF models)
955-808
Document Feed Dup
(CVT, DADF models)
955-810
Platen Open/Close Count
(CVT, DADF models)
955-829
Invert Solenoid ON Count 0
General procedures information
Initialize HFSI Counters
Initial
Setting
Value
Range
Count Condition
0
0~6,881,175 Scan Count (including pre-Scan)
Counts up with each scan.
HFSI to Scan count after clearing HFSI Counter
Recycle to Total Scan count without clearing
0
0~7,864,200 Lamp ON Time
Starts timing when the lamp turns on.
Stops timing when the lamp turns off.
Writes to the NVM during CRG Initialize.
HFSI to Lamp ON time after clearing HFSI
Counter
Recycle to Total Lamp ON time without clearing
0
0~6,881,175 Lamp ON count after clearing HFSI Counter
Counts up when the lamp turns on.
Writes to the NVM during CRG Initialize.
0
0~1,966,050 Counts up when the Angle Sensor is forced fully
open.
0
0~5,000,000 Counts up when the Feed Sensor turns on.
HFSI to Document Feed count after clearing HFSI
Counter
Recycle to Total Document Feed count without
clearing
0
0~5,000,000 Counts the no. of document sheets fed in Simplex
mode.
0
0~5,000,000 Counts the no. of document pages fed in Duplex
mode.
Counts up when Invert Sensor turns off during
Duplex transport.
0
0~1,000,000 Counts up when the Platen Interlock is open.
0~5,000,000 Counts up when the Invert Solenoid turns on.
HFSI to Invert Solenoid ON count after clearing
the counter
Recycle to Total Invert Solenoid ON count without
clearing
Table 2 IIT HFSI
Remarks
1 time increments
Max count value=above 6,000,000 times
Only count Platen Scans, not CVT Scans.
Lamp Life 2000 hours
1 time increments
Max count value=7,200,000sec and above
Times the total duration when the lamp is on (including AGOC, Lamp Check).
Lamp Life 6,000,000 times
1 time increments
Max count value=above 6,000,000 times
Counts the no. of times the lamp turns on (including AGOC, Lamp Check).
1 time increments
Max count value=above 1,000,000 times
No. of sheets fed from the CVT Tray
The NVM is controlled by the CVT.
The NVM is controlled by the CVT.
* Life is common to 955-808.
The NVM is controlled by the CVT.
* Life is common to 955-807.
Belt/CVT judgement is processed in the IISS.
The NVM is controlled by the CVT.
CVT(PF2)
The NVM is controlled by the CVT.
January 2007
6-174
Reversion 4.0
WorkCentre 7132